“Tool table?” error message in Test Run mode
NC FAQ1011
Question:
In the TEST RUN mode the error message “Tool table ?” appears when testing a program.
Answer:
Presumably no tool table is active for the TEST RUN mode of operation. In order to activate a tool table for TEST RUN:
> Select the Test Run operating mode
> Call the file manager (PGM MGT)
> Press the SELECT TYPE soft key to select the file type
> Press the SHOW .T soft key to show files of type .T
> Select the file (*.T) with the ENT key or the SELECT soft key
The TNC identifies a tool table active for TEST RUN with an “S” in the STATUS column.