In our NC Solutions database you will find solutions for frequently required tasks

BLK FORM cannot be displayed

NC FAQ1008

Question:

 Why can’t a BLK FORM created on an iTNC 530 be displayed by a TNC 426?

1 BLK FORM 0.1 Z X+0 Y+0 Z-1

2 BLK FORM 0.2 X+1000 Y+700 Z+0  

Answer:

On the TNC 426 / 430 the ratio of the shortest to longest side of the BLK FORM must be less than 1 to 64. In your BLK FORM the Z value is less than 1 : 64 of the X value.

Solution: Program the blank with dimensions that can be displayed. 

Product type

Test run Programming Machine control Programming station Programming station VirtualBox FAQ iTNC 530 TNC 426/430